Servocuna Resuscitaire Neonatal Infant Radiant Warmer with X-ray Cassete

Model NO.: IRW-9300
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: No
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: No
X-ray Cassette: Yes
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Model NO.: IRW-9300
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: No
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: No
X-ray Cassette: Yes
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Servocuna Resuscitaire Neonatal Infant Radiant Warmer With X-ray Cassete

Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
Set temperature and baby temperature can be displayed separately;
Horizon angle of warmer module and inclination of the bassinet can be adjusted;
The panels around bassinet can be turned outward;
X-ray cassette under the bassinet;
APGAR timer;
Timer to count phototherapy time;
Failure alarm indication;
RS232 connector.

Standard Configuration:
IRW-9300: warmer module, bassinet, main column, mobile stand, controller, I.V. Pole and tray.
IRW-9300B: based on IRW-9300, added with the phototherapy unit.
IRW-9300A: based on IRW-9300B, added with the breath resuscitation bag, infant head fixing unit, the oxygen supplying set ( the oxygen cylinders, buoy type oxygen regulator, wall type oxygen regulator),low-pressure suction.

Optional Configuration:
Disposable skin temperature sensor, Vertical height adjustment (VHA) stand and Weighing system

Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 700VA (IRW-9300)
                   AC220V-230V/50Hz or AC110-120V/50-60Hz, 750VA (IRW-900B,IRW-9300A)
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Angle of heater head: 0°,30°,60° for two ways
Inclination of the bassinet: ±10°
APGAR timer: audible and visible  alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
The total irradiance Ebi on the effective surface area: ≥0.66mW/cm2 (IRW-900B,IRW-9300A)
Average value of general bilirubin radiation on the mattress effective range: ≥0.58mW/cm2 (IRW-900B,IRW-9300A)
Bilirubin uniformity of radiating on the mattress effective range: >0.4(IRW-900B,IRW-9300A)
Dominant wavelength of blue light: 400-550nm
  Servocuna Resuscitaire Neonatal Infant Radiant Warmer With X-ray Cassete

Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
Set temperature and baby temperature can be displayed separately;
Horizon angle of warmer module and inclination of the bassinet can be adjusted;
The panels around bassinet can be turned outward;
X-ray cassette under the bassinet;
APGAR timer;
Timer to count phototherapy time;
Failure alarm indication;
RS232 connector.

Standard Configuration:
IRW-9300: warmer module, bassinet, main column, mobile stand, controller, I.V. Pole and tray.
IRW-9300B: based on IRW-9300, added with the phototherapy unit.
IRW-9300A: based on IRW-9300B, added with the breath resuscitation bag, infant head fixing unit, the oxygen supplying set ( the oxygen cylinders, buoy type oxygen regulator, wall type oxygen regulator),low-pressure suction.

Optional Configuration:
Disposable skin temperature sensor, Vertical height adjustment (VHA) stand and Weighing system

Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 700VA (IRW-9300)
                   AC220V-230V/50Hz or AC110-120V/50-60Hz, 750VA (IRW-900B,IRW-9300A)
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Angle of heater head: 0°,30°,60° for two ways
Inclination of the bassinet: ±10°
APGAR timer: audible and visible  alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
The total irradiance Ebi on the effective surface area: ≥0.66mW/cm2 (IRW-900B,IRW-9300A)
Average value of general bilirubin radiation on the mattress effective range: ≥0.58mW/cm2 (IRW-900B,IRW-9300A)
Bilirubin uniformity of radiating on the mattress effective range: >0.4(IRW-900B,IRW-9300A)
Dominant wavelength of blue light: 400-550nm
 

Metallurgical Microscopes

Student Microscope,Biological Microscope,Monocular Microscope

Boda Medical Products Co., Ltd. , http://www.nbmedicals.com